v-series_appliances

Vendor: websense

Actively Exploited 0 CISA KEV List
PoC / Exploits 1 Code Available
Total RCEs 1 Remote Access
Total CVEs 33 Total Indexed
Avg. EPSS 2.45% Exploit Prob.
Latest CVE CVE-2015-2773 Mar 27

Security Vulnerability Index

Page 1 / 4
5.0 CVSS

SVM in Websense TRITON V-Series appliances before 8.0.0 allows attackers to read arbitrary files via unspecified vectors.

EPSS: 0.26%
7.5 CVSS

SVM in Websense TRITON V-Series appliances before 8.0.0 allows attackers to upload arbitrary files via unspecified vectors.

EPSS: 0.35%
5.0 CVSS

The Mail Server in Websense TRITON AP-EMAIL and V-Series appliances before 8.0.0 uses plaintext credentials, which allows remote attackers to obtain sensitive information via unspecified vectors.

EPSS: 0.23%
6.8 CVSS

Cross-site request forgery (CSRF) vulnerability in the command line page in Websense TRITON V-Series appliances before 8.0.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.

EPSS: 0.12%
4.3 CVSS

Cross-site scripting (XSS) vulnerability in Websense TRITON AP-EMAIL before 8.0.0 and V-Series 7.7 appliances allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

EPSS: 0.26%
4.0 CVSS

Websense TRITON V-Series appliances before 7.8.3 Hotfix 03 and 7.8.4 before Hotfix 01 allow remote administrators to read arbitrary files and obtain passwords via a crafted path.

EPSS: 0.27%
5.0 CVSS

Websense TRITON AP-WEB before 8.0.0 does not properly restrict access to files in explorer_wse/, which allows remote attackers to obtain sensitive information via a direct request to a (1) Web Security incident report or the (2) Explorer configuration (websense.ini) file.

EPSS: 0.30%
4.3 CVSS

Multiple cross-site scripting (XSS) vulnerabilities in the data loss prevention (DLP) incident Forensics Preview in Websense Triton 7.8.3 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via a crafted (1) email or (2) HTTP request, which triggers a DLP Policy.

EPSS: 0.26%
6.5 CVSS
CVE-2015-2746
RCE Exploit Found

The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.

EPSS: 23.89%
4.3 CVSS

Multiple cross-site scripting (XSS) vulnerabilities in Websense TRITON AP-WEB before 8.0.0 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via the (1) ws-userip in the ws-encdata parameter to cve-bin/moreBlockInfo.cgi in the Data Security block page or (2) admin_msg parameter to configure/ssl_ui/eva-config/client-cert-import_wsoem.html in the Content Gateway, which is not properly handled in an error message.