RUCKUS SmartZone (SZ) before 6.1.2p3 Refresh Build allows ../ directory traversal to read files.
ruckus_r720
Vendor: commscope
Security Vulnerability Index
Page 1 / 3In RUCKUS SmartZone (SZ) before 6.1.2p3 Refresh Build, OS command injection can occur via an IP address field provided by an authenticated user.
RUCKUS SmartZone (SZ) before 6.1.2p3 Refresh Build allows OS command injection via a certain parameter in an API route.
Ruckus SmartZone (SZ) before 6.1.2p3 Refresh Build allows authentication bypass via a valid API key and crafted HTTP headers.
RUCKUS SmartZone (SZ) before 6.1.2p3 Refresh Build has a hardcoded SSH private key for a root-equivalent user account.
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, and in Ruckus ZoneDirector prior to 10.5.1.0.279, where the authenticated configuration endpoint `/admin/_conf.jsp` writes the Wi-Fi guest password to memory with snprintf using the attacker-supplied value as the format string; a crafted password therefore triggers uncontrolled format-string processing and enables remote code execution on the controller.
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, where the authenticated diagnostics API endpoint `/admin/_cmdstat.jsp` passes attacker-controlled input to the shell without adequate validation, enabling a remote attacker to specify a target by MAC address and execute arbitrary commands as root.
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.14 and 200.17.7.0.139, where the functions `stamgr_cfg_adpt_addStaFavourite` and `stamgr_cfg_adpt_addStaIot` pass a client hostname directly to snprintf as the format string. A remote attacker can exploit this flaw either by sending a crafted request to the authenticated endpoint `/admin/_conf.jsp`, or without authentication and without direct network access to the controller by spoofing the MAC address of a favourite station and embedding malicious format specifiers in the DHCP hostname field, resulting in unauthenticated format-string processing and arbitrary code execution on the controller.
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.27 and 200.18.7.1.323, and in Ruckus ZoneDirector prior to 10.5.1.0.282, where a path-traversal flaw in the web interface lets the server execute attacker-supplied EJS templates outside permitted directories, allowing a remote unauthenticated attacker who can upload a template (e.g., via FTP) to escalate privileges and run arbitrary template code on the controller.
An issue was discovered in CommScope Ruckus Unleashed prior to 200.15.6.212.27 and 200.18.7.1.323, and in Ruckus ZoneDirector prior to 10.5.1.0.282, where an authenticated request to the management endpoint `/admin/_cmdstat.jsp` discloses the administrator password in a trivially reversible obfuscated form. The same obfuscation method persists in configuration prior to 200.18.7.1.302, allowing anyone who obtains the system configuration to recover the plaintext credentials.